To ensure that leaks are measured as the correct amount of gas, we have been audited under a program run by an accredited organization and are certified as an organization that can provide official calibration services.
Accredited calibration of your measuring equipment increases compliance with various relevant standards for metrological traceability of your measuring equipment.
|
Base on the Measurement Law, Certified by
IA Japan
※1
JCSS Calibration Certification Symbol |
Based on ISO Standard, Certified by
JAB
※2
ISO/IEC 17025 Calibration Accreditation Symbol |
|
|
※1: IA JAPAN is an accreditation body under NITE (National Institute of Technology and Evaluation), responsible for conformity assessment accreditation.
※2: JAB (Japan Accreditation Board), a public interest incorporated foundation, is an accreditation body that accredits testing laboratories, calibration organizations, and others in conformity with international standards.
Using accredited and calibrated equipments ensure conformity to the various plans used by your company.
Reliable traceability (calibration chain)to national or international standards is required, and calibration by an accredited laboratory satisfies these requirements, which is expected to help and simplify the management of measuring instruments on the customer’s side.
Accreditation audits by certification bodies also cover calibration capabilities, including the content and procedures of calibration work, as well as uncertainty estimates, ensuring a high level of reliability in the results obtained from calibration work.
The following “Calibration Certificate” issued by our company is recognized in ILAC member countries that have signed an international mutual recognition agreement, and is extremely useful as evidence.
| Sample of JCSS Calibration Certificate | Sample of ISO/IEC 17025 Calibration Certificate |
| Certification Categories | JCSS Calibration (Pressure Category Leakage Meter) |
ISO/IEC17025 Calibration (Mechanical Quantity Gas Flow Rate) |
||
|---|---|---|---|---|
| Calibration Range |
1.0 × 10⁻⁶ ~ 8.6 × 10⁻³ Pa・m³ / s (Equivalent to 0.0006 ~ 5.0 mL / min) |
1.0 ~ 1,000 mL / min | ||
| Calibration Pressure | Input Pressure | Output Pressure | Input Pressure | Output Pressure |
| Pressurized | 0 ~ 900 kPa G | Atm. | 0 ~ 800 kPa G | 101.325 kPa abs |
| Depressed | Atm. | ≦ 150 Pa abs | 101.325 kPa abs | -80 ~ -10 kPa G |
| Calibration Medium |
< 1.7 × 10⁻⁴ Pa・m³ / s: Air, N₂, 5% H₂, He ≧ 1.7 × 10⁻⁴ Pa・m³ / s: Air, N₂ |
Air | ||
| Calibration Items | Standard Leak | Capillary Flow Meter, Mass Flow Meter, Gas Flow Meter | ||
Inquiry
Please contact your nearest sales office.
Asking you for information about the item you are considering calibrating.
Quotation
Provideing our quotation on the same day based on your information about your item.
If you would like a method other than our standard calibration, please let us know. We will provide you with a quote based on your desired content.
Ordering・Sending the item
We look forward to receiving your order. Please allow us to keep the requested items at the same time.
※Please be aware that we may not be able to accept your request for calibration if the requested item is contaminated.
Calibration
Carry out the calibration work.
Delivery
We will return the calibration items entrusted to us.
At the same time, we will provide the Calibration Certificate.