This fully-automatic system conducts leak testing while controlling the bombing (Helium charge), gross leak test, and fine leak test conditions.
Test piece size(mm) | 2.0×1.6~3.2×2.5 |
---|---|
Process Capacity | 12ch 0.8s/part(Bombing : 60min) |
Judgment Level(Pa・m³/s) | Gross Leak:2×10⁻⁷~Large leak(Equivalent standard leak) Fine Leak:1×10⁻⁹~(He) |
Power Source/Applied Current | AC200V±10% Three-phase 50/60Hz / 4kVA |
Pneumatic Pressure Source | 0.5 MPa pr above |
External Dimensions (mm) | W1600×D1000×H1800 *signal tower excluded |